Maxon WL7-vers. C Spezifikationen Seite 39

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 107
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 38
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
39
PATENTS PENDING
1. Position the platform at oor level
(FIG. 39-1).
2. Turn OFF power switch on pump
cover (FIG. 39-1).
PLATFORM AT FLOOR LEVEL
(LH SIDE SHOWN)
FIG. 39-1
POWER
SWITCH
INBOARD SWITCH ADJUSTMENT
NOTE: Do this procedure if structure of the Lift is undamaged and:
• The Controller reads “IBRS SW” when Inboard Rollstop is locked in the up
position.
• Inboard Switch is removed & replaced.
The adjustment is done correctly if:
• The Controller does not read “IBRS SW” when the Inboard Rollstop is
locked in the up position.
3. Using the manual backup pump (FIG. 39-2),
lower the platform until inboard rollstop
(IBRS) is locked in the up position (FIG. 33-
1). Refer to Operation Manual for instruc-
tions to operate the manual pump.
USING BACKUP PUMP TO UNFOLD
(LIFT WITH LH PUMP)
FIG. 39-2
RELEASE
VALVE
BACKUP PUMP
HANDLE
Seitenansicht 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 106 107

Kommentare zu diesen Handbüchern

Keine Kommentare