11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
15
PATENTS PENDING
ADJUSTMENTS
THRESHOLD (MAT) SWITCH ADJUSTMENT
NOTE: Do this procedure if structure of the Lift is undamaged and:
• The controller reads “MAT ERR” when the threshold plate is unoccupied
and platform is below fl oor level.
• The threshold warning beacons and threshold warning alarm are on
when threshold is unoccupied and platform is below fl oor level.
• The threshold warning beacons and threshold warning alarm will not turn on
when threshold is occupied and platform is below fl oor level.
• The threshold (MAT) switch (or switches) or threshold plate is removed &
replaced.
The adjustment is done correctly if:
• The controller does not read “MAT ERR” when the threshold plate is unoc-
cupied and platform is below fl oor level.
• The threshold warning beacons and threshold warning alarm turn on when
threshold is occupied and platform is below fl oor level.
LIFT AT GROUND LEVEL
FIG. 15-1
POWER SWITCH
1. Make sure power switch
is turned on. Lower Lift to
the ground (FIG. 15-1).
Kommentare zu diesen Handbüchern