Maxon WL7-vers. C Spezifikationen Seite 104

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 107
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 103
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
104
PATENTS PENDING
ITEM READING CAUSE
1
Green LED and Red LED ash on
for .5 second
Battery power is connected to input of
the relay. To save power, relay enters
sleep mode until power is turned on at
the Lift.
2 Green LED on
Power switch was turned on at the Lift.
Relay output is on.
3 Green LED ashing fast Voltage is above 16.5 V.
4 Green LED ashing slowly Voltage is below 8.0 V.
5 Red LED ashing fast Over current.
6 Red LED ashing slowly High temperature (over 100° C).
7 Red LED displays 3 short ashes Short in FET.
8 Red LED displays 2 short ashes Open in FET.
DC RELAY READINGS
NOTE: A fast ash is 5 ashes per second.
A slow ash is 1 ash per second.
FIG. 104-1
GREEN LED
RED LED
DC RELAY
The DC Relay (FIG. 104-1) is a
solid-state device for switching DC
load current of up to 100 amps. Un-
like a motor start switch (relay), the
DC Relay uses only a few milliamps
of current and has LED’s to indicate
normal operation or fault conditions
(FIG. 104-1 and TABLE 104-1).
When the power switch on the Lift
is turned on, it checks for power-re-
lated faults before applying power to
the Lift. If a fault is detected, the DC
Relay will not apply power to the Lift,
and the green LED or red LED will
indicate the applicable fault (TABLE
104-1).
TABLE 104-1
POWER OUTPUT
(REF)
POWER INPUT
(REF)
Seitenansicht 103
1 2 ... 99 100 101 102 103 104 105 106 107

Kommentare zu diesen Handbüchern

Keine Kommentare