Battery voltage is below 12.2 volts. Controller allows the Lift to operate until battery voltage
drops below 11.9 volts.
Corrective action:
1. Start the vehicle to charge battery.
2. If that does not help, check if the battery is bad.
3. If the battery is OK, check to see if it is charging.
4. If battery is not charging, make sure the power cable and ground cable are in good
condition, and the connections on both ends are clean and tight.
CHRG BAT:
This reading appears when the platform is being raised or lowered and the battery volt-
age is below 11.9 volts. The controller will only allow the platform to be raised, folded, and
stowed until battery is re-charged.
Corrective action:
1. Start the vehicle to charge battery.
2. If that does not help, check if the battery is bad.
3. If the battery is okay, check to see if it is charging.
4. If battery is not charging, make sure the power cable and ground cable are in good
condition, and the connections on both ends are clean and tight.
LOW BAT:
NOTE: Battery isolator devices, in the power supply circuit for the Lift, can drop
enough voltage to produce a fault reading on the controller. MAXON recom-
mends that a battery isolator should not be used in the power supply circuit
for the Lift.