Maxon WL7 Spezifikationen Seite 19

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 91
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 18
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
19
PATENTS PENDING
LH SIDE OF LIFT
FIG. 19-1A
ADJUSTING SWITCH
FIG. 19-1B
THRESHOLD
PLATE
THRESHOLD
WARNING BEACON
4. Turn the MAT switch adjustment screw
(FIGS. 19-1B and 19-2) clockwise until
threshold warning alarm and beacons acti-
vate (FIG. 19-1A). Then, turn adjustment
screw counter-clockwise (FIG. 19-2) ap-
proximately 1-1/2 turn. Warning alarm and
beacons should turn off.
5. Step on threshold plate. Warning alarm
and beacons should activate. If the warning
alarm and beacons do not activate, slightly
turn adjustment screw (FIGS. 19-1B and
19-2) clockwise. Repeat until warning
alarm and beacons activate when stepping
on threshold plate and deactivate stepping
off threshold plate.
MAT SWITCH ADJUSTMENT SCREWS
FIG. 19-2
CW - UNTIL ALARM &
BEACONS TURN ON
1-1/2 TURN CCW - ALARM
& BEACONS TURN OFF
BASE
PLATE
ADJUSTMENT
SCREW
THRESHOLD
WARNING ALARM