Seitenansicht 16
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
17
PATENTS PENDING
1. Make sure power switch
(FIG. 17-1A) is turned
on. Lower Lift to the
ground (FIG. 17-
1A).
ADJUSTMENTS
MAT SWITCH ADJUSTMENT
LIFT AT GROUND LEVEL
(RH SIDE SHOWN)
FIG. 17-1A
POWER SWITCH
HEIGHT MEASUREMENT
(RH SIDE SHOWN)
FIG. 17-1B
5/8”
NOTE: Do this procedure if structure of the Lift is undamaged and:
• The controller reads “MAT ERR” when the threshold plate is unoccupied
and platform is below oor level.
• The threshold warning beacons and threshold warning alarm are on
when threshold is unoccupied and platform is below oor level.
• The threshold warning beacons and threshold warning alarm will not turn on
when threshold is occupied and platform is below oor level.
• The MAT switch or threshold plate are removed & replaced.
The adjustment is done correctly if:
• The controller does not read “MAT ERR” when the threshold plate is unoc-
cupied and platform is below oor level.
• The threshold warning beacons and threshold warning alarm turn on when
threshold is occupied and platform is below oor level.
2. Measure the height of the
threshold plate as shown in FIG.
17-1B. If the height is 5/8”,
go to step 4 (skip step 3). If the
height is not 5/8”, go to step 3.
Seitenansicht 16