11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
19
PATENTS PENDING
4. Raise the lift to Vehicle Floor level
(FIG. 19-4). Then lower the Lift to
the ground (FIG. 18-1). Controller
should display GROUND (FIG. 19-
3) .
5. Use the Manual Pump (FIG. 18-2)
to raise the Lift so the top surface
of Platform is 3” above ground
(FIG. 19-1). Controller (FIG. 18-2)
should display UP (FIG. 18-3).
PLATFORM 3” ABOVE GROUND
FIG. 19-1
3. Turn the GROUND switch adjustment
screw (FIG. 19-1) counter-clockwise (FIG.
19-2) until switch “clicks” and Controller
displays GROUND (FIG. 19-3). Next turn
GROUND switch adjustment screw clock-
wise (FIG. 19-3) until switch “clicks” and
Controller displays UP (FIG. 18-3).
3”
ADJUSTMENT
SCREW
LIFT AT FLOOR LEVEL
FIG. 19-4
GROUND SWITCH ADJUSTMENT SCREW
FIG. 19-2
CCW -
UNTIL CONTROLLER
READS “GROUND”
GROUND
CW -
UNTIL CONTROLLER
READS “UP”
CONTROLLER READING -
PLATFORM AT GROUND LEVEL
FIG. 19-3