11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
13
PATENTS PENDING
5. Pull out (no threads) Filler Cap (FIG. 12-2).
Fill the Reservoir with Hydraulic Fluid
(TABLE 13-1) to level (“FL1”) you mea-
sured in step 2. Reinstall Filler Cap (FIG.
12-2)
7. Bolt on the Pump Cover as shown in
FIG. 12-1. Torque the 5/16”-18 cover
screws to approximately 20 LBS.-FT.
3. Disconnect the 2 tubes from barbed
fittings on the Reservoir (FIG. 13-1).
Unbolt the Reservoir from Pump.
Remove the Reservoir and pour the
used hydraulic fluid into a drain pan.
6. Stow the Lift. Check the Hydraulic Fluid level
in Reservoir as follows. Measure length “L”
of Reservoir. With Liftgate stowed, level
“FL” should be as shown in FIG. 13-2 and
TABLE 13-2.
HYDRAULIC FLUID LEVEL
(LH PUMP SHOWN)
FIG. 13-2
4. Bolt the Reservoir on the Pump.
(FIG. 13-1). Reconnect tubes to
barb fittings on the Reservoir.
UNBOLTING / BOLTING RESERVOIR
(LH PUMP SHOWN)
FIG. 13-1
TUBE
BARBED
FITTINGS
RESERVOIR
BOLTS
(4 PLACES)
PUMP
TUBE
TABLE 13-2
FILLER
CAP
RESERVOIR
“L”
“FL”
(SEE TABLE
13-1)
HTGNELRIOVRESER
)"L"(
LEVELDIULF
)"LF"(
"2/1-7"1
"2/1-9"3
TABLE 13-1
DIULFCILUARDYHDEDNEMMOCER
DNARBREBMUNTRAP
DAEMESOR11171DIULFSHT
NOXXE62IVHSIVINU
NOTE: WL7 may be equipped with 1 of 2
different sizes of Reservoir. To
make sure you have correct fluid
level, measure length of Reservoir
before checking fluid level.