PATENTS PENDING
CHECKING HYDRAULIC FLUID LEVEL
CAUTION
CAUTION
Keep dirt, water and other contaminants from entering the hydraulic sys-
tem. Before opening the hydraulic uid reservoir ller cap, drain plug and
hydraulic lines, wipe off contaminants that can get in the openings. Also,
protect the openings from accidental contamination.
2. If needed, add uid to the Reservoir
as follows. Pull out (no threads) Filler
Cap (FIG. 11-1). Fill the Reservoir
with Hydraulic Fluid (TABLE 11-1) to
level shown in FIG. 11-1. Reinstall
Filler Cap (FIG. 11-1).
1. Check the Hydraulic Fluid level in Reservoir
as follows. With Liftgate stowed, uid level
should be as shown in FIG. 11-1.
3. Bolt on the Pump Cover as shown
in FIG. 11-2. Tighten the 5/16”-
18 cover screws until snug.
BOLTING ON THE PUMP COVER
(LH PUMP SHOWN)
FIG. 11-2
SCREWS
FLAT
WASHERS
(3 PLACES)
PUMP COVER
FILLER
CAP
RESERVOIR
HYDRAULIC FLUID LEVEL
(LH PUMP SHOWN)
FIG. 11-1
TABLE 11-1
2”
RECOMMENDED HYDRAULIC FLUID
BRAND PART NUMBER
ROSEMEAD THS FLUID 17111
EXXON UNIVIS HVI 26